Each appliance below has notes for Reston homes, from the clustered townhouses around Lake Anne to the 1970s and 80s houses of Hunters Woods and South Lakes and the condo towers near the Silver Line.
Refrigerator repair in Reston
Reston kitchens span half a century, so refrigerators range from older units in tight openings to French-door models in new condos. Ice and water bring many of the calls. In September 2024 a GE Profile in South Lakes stopped making ice and dispensed water slowly; the technician replaced the water filter head valve and a secondary water valve. In January 2026 a Kenmore in North Point had an ice dispenser that quit and a water dispenser that sometimes kept pouring after the lever was released, the sign of a valve or switch that does not shut off cleanly. Fairfax Water's hardness slowly scales ice maker valves, which a fridge filter does not prevent. Measure the opening before you replace an older refrigerator, since many were sized decades ago.
Refrigerator repair in Reston
Freezer repair in Reston
You will find old uprights in Reston townhouse storage rooms and drawer freezers in the newer condos. In July 2026 a Whirlpool in 20191 would not get its freezer down to 0°F. The first checks are the same on any of them: a clean condenser, a running evaporator fan and no frost on the back panel, because frost there tells us the defrost cycle is no longer melting the coil clean. Drawers bring a fault of their own. In March 2025 a Fisher & Paykel bottom-freezer in Hunters Woods would not close flush and frost built up on the drawers, and the repair was new slide rails and a realigned door hinge. Leave some breathing room behind and above any freezer tucked under the stairs or into a closet.
Freezer repair in Reston
Washer repair in Reston
Laundry in older Reston townhouses is often an upstairs closet or the basement, and the hookups have sometimes been redone more than once. In January 2024 a Samsung front-loader in Tall Oaks showed 4E, a fill timeout; its inlet screens were clogged, and the screens and dual inlet valve were replaced. In December 2023 another Samsung in 20190 filled and spun but stopped partway through, a pattern that often means water is draining too slowly for the washer to reach full spin. In October 2026 an Electrolux front-loader in 20190 needed a new door bellows. While the washer is pulled out, check that its drain hose is not pushed deep into the standpipe, which can siphon water out as it fills.
Washer repair in Reston
Dryer repair in Reston
Older Reston townhouses often vent their dryers through long, bent runs patched during remodels, with foil or vinyl transition ducts and outside flaps that stick. In July 2025 an LG gas dryer in Lake Audubon shut off after about five minutes and showed d80, meaning the exhaust was badly restricted; the technician cleared lint from inside the duct and replaced the high-limit thermostat. Worn parts fail too. In June 2024 a stacked Whirlpool dryer near Reston Town Center hummed while the start button was held but would not turn, and a new belt and idler pulley fixed it. The condo buildings near the Silver Line also have ventless and stacked dryers, and their lint filters and condensers need cleaning more often than most owners expect.
Dryer repair in Reston
Dishwasher repair in Reston
Reston kitchens have often been remodeled more than once, and each remodel can change the dishwasher's drain routing, sometimes losing the high loop or air gap along the way. When one will not drain or begins to smell, we follow the whole drain path before blaming the pump. Heating faults show up as cold washes and wet dishes. In April 2024 a Bosch 500 Series in North Point needed a new flow-through heater and a relay on its control module. Film on glasses is more often hard water than a fault, and Fairfax Water's hardness varies by plant and season, so set the rinse aid and the hardness setting to match. Write down any code; our Bosch dishwasher codes page covers that brand.
Dishwasher repair in Reston
Oven repair in Reston
Ovens in Reston span the same fifty years as the houses. An original-era range relies on a mechanical thermostat and bare elements, while a newer electronic oven adds sensors, a convection fan, a self-clean lock and coded errors. An oven that bakes unevenly often has a stopped convection fan, an element that only partly heats, or a door gasket leaking heat so one side browns faster. After self-clean, give the oven time to cool completely before worrying about a locked door, since many release on their own once cool. Before booking, check the temperature with a thermometer at 350 and write down any code. Foil on the floor of a gas oven can smother the bake burner's vents and mark the enamel, so leave it out.
Oven repair in Reston
Stove, range and cooktop repair in Reston
Reston cooks on almost everything: electric coil ranges, smooth-tops, gas, the downdraft cooktops of older remodels and the induction tops in newer condos. In December 2024 a burner on a Dacor electric cooktop in Sunset Hills would not hold its heat setting, and the infinite switch and the dual-element wiring harness were replaced. On a coil range, moving a working coil into the dead spot is the quickest test; if it stays cold there, the receptacle or switch has failed. A smooth-top zone stuck on high needs a new infinite switch, so keep the range off at the breaker until the repair. On gas, clear the burner ports and seat the caps before booking. Tell us the fuel and whether the oven side has also stopped heating.
Stove and range repair in Reston · Cooktop repair in Reston
Microwave repair in Reston
Many Reston remodels swapped the range hood for an over-the-range microwave, and condos near Town Center add drawer and wall-mounted units. Those built-in styles cost enough to replace that a repair usually wins. When the turntable stops, check that the glass tray and roller ring sit properly before suspecting the motor or the coupler under the tray. Food that stays cold while the unit runs means a high-voltage part, which a technician tests with the power cut and the capacitor discharged. Arcing inside the cavity should stop all use until the cause, often a burned waveguide cover or chipped paint, is fixed. If the display went dark during a power outage, say so when you book, since a fuse or the board may have taken the surge.
Microwave repair in Reston
Range hood repair in Reston
Broan hoods are common in Reston's builder-grade kitchens, and one of our Reston jobs was a Broan whose exhaust fan motor had locked up; a new blower motor and fan speed switch put it right. Seized motors usually give warning. As grease coats the blower wheel and bearings, the fan slows and grows louder for weeks before it stops, so a hood that has started to sound different is worth cleaning and checking early. Townhouse hoods often vent through the roof or a wall with a damper at the end, and a damper stuck shut leaves a fan that sounds normal but moves little air. Recirculating hoods need a fresh charcoal filter every few months. If the lights fail, confirm the bulb type before suspecting the socket.
Range hood repair in Reston
Wine cooler repair in Reston
Built-in undercounter wine coolers are common in Reston's newer condos, and those units vent through the front grille, so keep rugs, boxes and dust away from it. Condensation on the inside of the glass or along the back wall usually points to room air sneaking past the door. A dollar bill shut in the door at a few spots makes a quick seal test: where it pulls out with no resistance, the gasket has stopped sealing. A cooler that sits out of level will not swing shut and seal on its own. If the compressor runs constantly while the temperature creeps up, listen for the interior fan, which is a common and fixable failure. A clogged drain at the back can also leave water pooling on the cabinet floor.
Wine cooler repair in Reston
Heating and cooling (HVAC) repair in Reston
Heat pumps heat many Reston townhouses and condos. On a cold morning, a few minutes of cool air from the vents is usually the defrost cycle at work, while a system that leans on its backup heat all day shows up on the electric bill. Many townhouse outdoor units are squeezed between a patio fence and the shrubs, and they need a couple of feet of open air on every side. In the condo towers by the Silver Line, each unit commonly has its own fan coil or compact air handler, fed either by its own heat pump outside or by building-supplied cooling; ask the management office which, since that decides who is responsible for the repair. Moving an outdoor unit usually needs Reston Association or cluster approval first.
HVAC repair in Reston