| Convection steam ovens |
| E01 | Control board upset by moisture or electrical interference | Check, then call if it returns |
| E02 | Control board upset by moisture or electrical interference | Check, then call if it returns |
| E03 | Incorrect process data, or moisture on the control board | Check, then call if it returns |
| E04 | Process data or software reload error | Check, then call if it returns |
| E06 | Control processor fault | Needs a technician |
| E09 | Temperature (PT) sensor or its wiring shorted | Needs a technician |
| E13 | Heating relay, temperature sensor or control fault | Needs a technician |
| E16 | Program timed out while waiting for you | Usually a quick fix |
| E17 | Food probe shorted, probe tip too hot, or socket wet | Check, then call if it returns |
| E18 | Food probe or its socket has a broken or loose contact | Check, then call if it returns |
| E25 | Climate sensor shorted, or exhaust or sensor duct blocked | Needs a technician |
| E26 | Climate sensor connection broken, or exhaust or sensor duct blocked | Needs a technician |
| E29 | Cooking compartment is not sealing | Check, then call if it returns |
| E35 | Cabinet opening around the oven is too hot | Check, then call if it returns |
| E38 | Installation niche temperature is too high | Check, then call if it returns |
| E42 | Fault needing service; Wolf gives no owner-level cause | Needs a technician |
| E44 | Steam generator heating fault or overheat protection tripped | Needs a technician |
| E52 | Water tank valve is not sealing | Needs a technician |
| E69 | Steam generator scaled, inlet valve leaking, or foam after descaling | Needs a technician |
| E70 | Steam generator scaled up, or water inlet valve leaking | Check, then call if it returns |
| E74 | Descaling problem: no descaler detected, or foam | Check, then call if it returns |
| E78 | Drain level sensor dirty or faulty (drain problem) | Usually a quick fix |
| E87 | Exhaust slide valve stuck, or its motor is faulty | Needs a technician |
| E110 | Operating system issue or moisture on the control board | Check, then call if it returns |
| E114 | Operating system or control board issue | Check, then call if it returns |
| BOILER SCALED UP, PLEASE DESCALE | Steam generator needs descaling | Usually a quick fix |
| APPLIANCE BLOCKED, DESCALING NECESSARY | Oven is blocked until it is descaled | Check, then call if it returns |
| DO NOT REMOVE WATER TANK | Hot water is still being pumped out of the boiler | Usually a quick fix |
| Convection steam ovens with touch control |
| E101 | Touch control lost communication with the control board | Check, then call if it returns |
| E102 | Touch control lost communication with the relay board | Check, then call if it returns |
| E103 | Operating system or board compatibility problem | Check, then call if it returns |
| E133 | Control fault; Wolf gives no specific cause | Check, then call if it returns |
| Wall ovens, ranges and steam ovens with a probe socket |
| PROBE? | Oven cannot detect the temperature probe | Usually a quick fix |
| Legacy convection steam ovens |
| E05 | Control error; Wolf gives no specific cause | Check, then call if it returns |