| Legacy dual-fuel ranges (2002-2020) |
| ERR 01 | Door lock switches not sensed within 60 seconds | Check, then call if it returns |
| ERR 02 | Oven overheated past its safety limit | Needs a technician |
| ERR 03 | Oven temperature sensor (RTD) open circuit | Needs a technician |
| ERR 04 | Oven temperature sensor (RTD) short circuit | Needs a technician |
| ERR 07 | Internal (SPI) communication lost to the control board | Check, then call if it returns |
| ERR 08 | Control memory checksum wrong at power-up | Check, then call if it returns |
| ERR 09 | Meat probe reads as shorted | Check, then call if it returns |
| ERR 10 | Control upset by a power surge or outage | Check, then call if it returns |
| 0E | Power relay sensed closed when it should be open | Needs a technician |
| KEY COMM | Control panel lost communication with the oven controller | Needs a technician |
| Legacy induction ranges |
| 20 | Wrong supply connection, or input above 300 volts | Needs a technician |
| 31 | Invalid control configuration | Check, then call if it returns |
| 36 | Internal (TC) temperature too high | Check, then call if it returns |
| E4 | Configuration implausible (control board issue) | Check, then call if it returns |
| E6 | Electrical supply error | Check, then call if it returns |
| E7 | Unspecified error, usually shown with another code | Check, then call if it returns |
| Dual-fuel ranges, 2021 and newer |
| 4321 | Left convection element not detected (load missing) | Needs a technician |
| 4421 | Oven cooling fan not detected or shorted | Needs a technician |
| 5222 | Power control (PCM) board area too hot | Needs a technician |
| 6020 | Control network (RS485) communication fault | Check, then call if it returns |
| L Series wall ovens and legacy dual-fuel ranges |
| COOL FAN | Cooling fan failure reported by its sensing switch | Needs a technician |
| LOWER RELAY | Lower oven relay circuit reported a failure | Needs a technician |
| Current dual-fuel ranges (2021+) and current induction ranges |
| 5521 | Primary cooling fan running too slowly (stalled) | Needs a technician |
| 5522 | Secondary cooling fan running too slowly (stalled) | Needs a technician |
| Induction ranges, current IR models (cooktop display) |
| E01 | Touch key error on the left secondary control | Check, then call if it returns |
| E40 | Induction generator hardware or sync error | Needs a technician |
| Induction ranges IR30450 and IR36550 (cooktop display) |
| E 05 | Induction generator not responding (LIN communication error) | Needs a technician |
| E 56 | Left secondary control board is too hot | Check, then call if it returns |
| All electric Wolf ovens (L, E, M Series; dual-fuel and induction ranges) |
| LO | Oven is still preheating; this is not a fault | Usually a quick fix |
| Wall ovens, ranges and steam ovens with a probe socket |
| PROBE? | Oven cannot detect the temperature probe | Usually a quick fix |
| L, Legacy E and M Series wall ovens; dual-fuel ranges (3031/3032 on 2021+ ranges) |
| PROBE SHORTED | Temperature probe or its connection has failed | Check, then call if it returns |
| Dual-fuel ranges (SAb on oven knob); L and E Series wall ovens (SABBATH) |
| SAb | Sabbath mode is on; this is not a fault | Usually a quick fix |
| Legacy dual-fuel ranges (2002-2020); shown on the oven knob |
| PF | Power failure, or oven too hot for the chosen mode | Usually a quick fix |
| Dual-fuel ranges, 2021 and newer with two ovens (right oven) |
| 0121 | Right oven convection element drive stuck closed | Needs a technician |
| Dual-fuel ranges, 2021 and newer (DF3050, DF3650, DF4850, DF6050 families) |
| 3C20 | Supply voltage to the range is too high | Needs a technician |