d80Exhaust vent restricted (number is percent blocked)
Check, then call if it returnsAlso shown as or same meaning as: d75, d90, d95
Common causes
- Full lint filter
- Lint-clogged, crushed or kinked vent duct
- Outside vent flap stuck shut
- Duct run too long
- Gas models: d80 can also mean no gas supply
What you can safely check
- Clean the lint filter
- Check the duct behind the dryer is not crushed or kinked
- Make sure the outside vent flap opens freely while the dryer runs
- Gas dryer: confirm the gas shutoff valve is open
- Have the vent line professionally cleaned
Call a technician if: Code stays after the vent is cleaned; blocked vents are a fire risk
Source: [1], [2]
tE1Temperature sensor (thermistor) problem
Needs a technicianAlso shown as or same meaning as: tE3
Common causes
- Faulty thermistor
- Temporary control glitch
What you can safely check
- Unplug the dryer or switch off its breaker
- Hold Start/Pause 5 seconds, restore power and try again
Call a technician if: Code returns after the reset; LG manuals say call for service
Source: [1], [2], [3], [4], [5], [6]
tE2Thermistor problem, usually in cold conditions
Check, then call if it returnsApplies to: All; LG notes it is most common on steam models in cold weather
Common causes
- Very cold laundry room or vent
- Snow or ice blocking the outside vent
- Faulty temperature sensor
What you can safely check
- Clean the lint filter
- Clear snow or ice from the outside vent hood
- Run a short, empty heated cycle to warm the dryer
Call a technician if: tE2 returns at normal room temperature
Source: [1], [2], [3], [4], [5], [6]
HSMoisture (humidity) sensor error
Check, then call if it returnsCommon causes
- Dryer-sheet or softener film on the sensor bars
- Faulty sensor
What you can safely check
- Wipe the metal sensor bars inside the drum, near the lint filter, with a damp cloth
- Let the bars dry fully before the next load
Call a technician if: HS returns after cleaning
Source: [1], [2], [3], [4], [5], [6]
PSWrong voltage or wiring at the power cord
Needs a technicianAlso shown as or same meaning as: Ps
Applies to: Electric dryers
Common causes
- Power cord wired incorrectly at the dryer
- Outlet or house wiring problem
What you can safely check
- Reset the dryer's double-pole circuit breaker
- Confirm the dryer is plugged into a proper 240V dryer outlet
Call a technician if: PS stays; have an electrician or technician check the cord wiring
Source: [1], [2], [3], [4], [5], [6], [7]
nPNo current reaching the heater
Check, then call if it returnsApplies to: Electric dryers
Common causes
- Tripped breaker or blown fuse
- House wiring or outlet problem
What you can safely check
- Switch the dryer's breaker off for 10+ seconds, then back on
- Check for a tripped breaker or blown fuse
Call a technician if: nP stays; have an electrician check the outlet voltage
Source: [1], [2], [3], [4], [5]
PFPower was interrupted, often after an outage
Usually a quick fixCommon causes
- Power outage
- Tripped breaker or blown fuse
What you can safely check
- Unplug the dryer or switch off its breaker
- Hold Start/Pause 5 seconds, restore power and restart
Call a technician if: PF repeats without any outage
Source: [1], [2], [3], [4], [5]
gASGas dryer is not getting gas
Check, then call if it returnsAlso shown as or same meaning as: GAS
Applies to: Gas dryers
Common causes
- House gas shutoff or dryer shutoff valve closed
- Gas service interrupted
- Kinked gas line
What you can safely check
- Confirm the house gas shutoff and dryer shutoff valve are fully open
- If you smell gas, leave the home and call the gas utility
Call a technician if: Valves are open but gAS stays; never adjust gas fittings yourself
Source: [2], [3], [4], [5]
dEDoor open or not fully closed
Usually a quick fixCommon causes
- Door opened mid-cycle
- Bulky load pushing the door open
- Lint filter not fully seated
- New door gasket still settling
What you can safely check
- Close the door firmly and press Start/Pause
- Push the lint filter fully into place
- Fill only about half the drum with bulky items
Call a technician if: Door is shut but dE stays
Source: [1], [2], [3], [7], [8]
dE4Door switch detection fault
Needs a technicianApplies to: Heat pump (ventless) dryers
What you can safely check
Call a technician if: Always book service
Source: [7]
F0Lint filter missing or not seated
Usually a quick fixAlso shown as or same meaning as: FO, INSERT FILTER
Common causes
- Lint filter not inserted fully
What you can safely check
- Pull out the lint filter and push it fully back into place
Call a technician if: Filter is seated but the code stays
Source: [1], [2]
Add WaterSteam water supply problem
Usually a quick fixAlso shown as or same meaning as: Add
Applies to: Steam models
Common causes
- Steam water feeder empty
- Feeder drawer not closed
What you can safely check
- Fill the steam feeder with tap water to the MAX line
- Close the feeder drawer fully and restart
Call a technician if: Message stays with the feeder filled
Source: [1], [2]
EHEDrum air temperature or humidity got too high
Check, then call if it returnsAlso shown as or same meaning as: ELE
Applies to: Some models (LG does not specify which)
Common causes
- High heat or humidity in the drum during a cycle
What you can safely check
- Remove the laundry
- Leave the door open about an hour to air out
- Check the dryer is level
Call a technician if: Notice keeps returning
Source: [2]
E13Drain hose blocked, or sump water frozen
Check, then call if it returnsApplies to: Hybrid condensing dryers only
Common causes
- Kinked, crushed or clogged drain hose
- Frozen water in the sump
What you can safely check
- Check the drain hose for kinks or clogs
- Use only the LG-supplied drain hose
- Press Start/Pause after correcting the hose
Call a technician if: E13 returns
Source: [1], [2]
OECondensed-water drain pump not working
Needs a technicianApplies to: Heat pump (ventless) dryers; not vented dryers
Common causes
- Drain pump fault
- Dryer installed below freezing
What you can safely check
- If the room is below freezing, warm it and retry
- Otherwise unplug the dryer
Call a technician if: OE stays in a warm room
Source: [7]
LE1Drum motor stopped suddenly
Needs a technicianApplies to: Heat pump (ventless) dryers
Common causes
- Overloaded drum
- Motor fault
What you can safely check
- Remove some laundry if the drum is overfull
- Unplug the dryer
Call a technician if: LE1 returns with a normal load
Source: [7]
LE2Heat pump compressor stopped suddenly
Needs a technicianAlso shown as or same meaning as: AE
Applies to: Heat pump (ventless) dryers
What you can safely check
Call a technician if: Always book service
Source: [7]
F1Drum temperature rose suddenly
Stop using itAlso shown as or same meaning as: FI
Applies to: Heat pump (ventless) dryers
Common causes
- Overheating inside the drum
What you can safely check
- Stop the dryer, unplug it, and remove the load once safe
Call a technician if: Always book service before using it again
Source: [7]
EEControl board memory (EEPROM) error
Needs a technicianCommon causes
- Main control board memory fault
What you can safely check
- Unplug for 10 minutes, then try again
Call a technician if: EE returns after the reset
Source: [3]
nFWi-Fi not registered (nF) or Wi-Fi module fault (nE)
Check, then call if it returnsAlso shown as or same meaning as: nE
Common causes
- Smart dryer not yet connected in the ThinQ app
- Wi-Fi module fault (nE)
What you can safely check
- Connect and register the dryer in the LG ThinQ app
- Restart the dryer after registering
Call a technician if: nE appears, or nF stays after registering
Source: [9]
CLControl lock is on (not a fault)
Usually a quick fixCommon causes
- Control/child lock turned on
What you can safely check
- Press and hold the Control Lock button for 3 seconds
Call a technician if: Lock will not turn off
Source: [2], [4]